Transformer Testing Technical Support

  • 1908-2025

    Can Tan Delta Help Predict Failures Before They Happen?

    This article explores the meaning of Dissipation Factor (DF), the relationship between Tan Delta and Quality Factor (Q), and how Tan Delta can predict equipment health for better performance and maintenance.

  • 0708-2025

    Other Necessary Tests about Transformer

    The article will focus on other necessary tests about transformer, such as AC withstand Voltage Test, Insulation dielectric performance test, Winding DC resistance measurement, CVT and so on.

  • 0608-2025

    Necessary Tests about Transformer

    This article will describe the necessary tests for transformers, focusing on insulation resistance measurement, dielectric loss factor and capacitance measurement, and partial discharge testing.

  • 0508-2025

    Why we measure Tan Delta?

    This article will focuses on some relative questions about Tan Delta Testing. It aims to help you know more deeply about TD Test.

  • 3107-2025

    CT and PT Testing Procedure

    This article will focus on the CT and VT testing procedure, and will also describe some specific operational details.

  • 2207-2025

    People also ask about ac impedence and dc impedence

    This article focuses on DC impedance and AC impedance, and will answer people's questions about these two impedances.

  • 1807-2025

    what is iec standards for tan delta test

    This article focuses on the IEC standard for the tan delta test, and will introduce the meaning of IEC 60851-5.

  • 1507-2025

    how to calculate no load losses of transformer

    This article focuses on how to calculate the no-load loss of the transformer, helping you understand the no-load loss more directly.

  • 1311-2024

    The meaning of winding resistance to transformer maintenance

    Among the many maintenance methods, the DC resistance test is widely used in routine transformer inspection. As an effective detection method, the DC resistance test can help engineers find potential problems in time and ensure the reliability and safety of the equipment.

  • 0909-2024

    Analysis of the causes of unbalanced transformer DC resistance test

    In the transformer DC resistance test, it will be found that the DC resistance value of the winding will be unbalanced, the reason can be divided into human factors, winding structure and material problems and transformer defects in three cases.

  • <