portable intelligent power underground cable fault locator
- Wrindu
- Shanghai, China
- about 10 working days
- 5000 set/month
- RDCD-850
RDCD - Ⅰ Cable Fault Test System is the result of Wrindu's continuous improvement and innovation for many years. The cable fault location system uses modern power electronic technology. Wrindu acoustic magnetic cable fault locator helps find underground cable faults with high sensitivity, noise reduction function, and accurate fault point detection.
RDCD-850 Cable Fault Locator, used with high voltage signal generator, is a portable and intelligent power cable fault locator.
Functional features
1. Background noise reduction helps remove unwanted sounds from the test site. As a result, the discharge sound at the fault point becomes easier to hear.
2. An intelligent algorithm calculates the acoustic and magnetic delay value for fixed-point detection. Testers can use the result directly without complicated manual calculation.
3. Moving the sensor activates the automatic mute function. This prevents handling noise from reaching the headset and also helps protect the operator's ears.
4. Cable direction can be checked with the built-in electronic compass. The screen also shows the sensor position and its angle during testing.
5. Sound filter settings are adjustable according to site conditions. Different frequency ranges can be selected when environmental noise affects the test.
6. Automatic gain control responds to the detected magnetic field signal. It adjusts the gain during fixed-point work, so manual adjustment is needed less often.
7. A noise-resistant monitoring headset is included for field use. It helps the operator monitor the detected sound during cable fault location.
8. For outdoor testing, the 800 × 480 color LCD remains easy to read. With brightness up to 800 cd/m², the screen can be viewed clearly in sunlight.
9. Power is supplied by a built-in high-capacity lithium-ion battery. Charging is available through the USB interface.
10. Its compact size and low weight make the equipment easy to carry. This is useful when technicians need to move between different cable testing points.
How Is the Acoustic Magnetic Fault Locator Used in the Field?
During underground cable testing, technicians first use the magnetic signal to confirm the cable route and locate the general fault area. The acoustic channel is then used to narrow down the fault position. When background noise is high, the operator can change the filter setting or use the noise reduction function.
For final fixed-point detection, the intelligent algorithm provides the acoustic and magnetic delay value. This helps technicians identify the fault point without relying only on manual judgment.
Why Does Acoustic and Magnetic Detection Matter?
Underground cable faults can produce both electromagnetic and acoustic signals. The magnetic channel helps technicians follow the cable and identify the testing area. After the fault area is narrowed down, the acoustic channel can help find the exact fault point.
For sites with strong interference, adjustable sound filters and noise reduction modes give operators more control over the signal they monitor.
Equipment parameters
| Category | Specification | Technical Details |
|---|---|---|
| Acoustic Magnetic Synchronous Fixed Point Function | Sound Channel | Supports multiple filtering modes, including all-pass, low-pass, high-pass, and band-pass filtering |
| Sound Channel Bandwidth | All-pass: 80 Hz–1500 HzLow-pass: 80 Hz–400 HzHigh-pass: 200 Hz–1500 HzBand-pass: 150 Hz–600 Hz | |
| Sound Signal Gain | ≥80 dB maximum signal gain for accurate cable fault point detection | |
| Fixed Point Accuracy | Up to 0.1 m, helping operators quickly locate underground cable fault positions | |
| Magnetic Channel | Maximum signal gain >80 dB for improved electromagnetic signal detection | |
| Acoustic Magnetic Synchronous Noise Reduction | Noise Reduction Modes | Supports three noise reduction modes: strong noise reduction, adaptive noise reduction, and no noise reduction |
| Application Advantage | Helps maintain accurate fault point identification in complex environments with strong background interference | |
| Power Supply System | Battery Type | Built-in lithium-ion battery pack |
| Battery Voltage | 3.7 V nominal voltage | |
| Battery Capacity | 6700 mAh | |
| Continuous Working Time | More than 9 hours of continuous operation | |
| Charger Input | AC 100–240 V, 50/60 Hz | |
| Charger Output | 5 V / 2 A | |
| Charging Time | Less than 5 hours | |
| Display System | LCD Display | 800 × 480 high-brightness color LCD screen |
| Outdoor Visibility | Sunlight-readable display for outdoor cable fault testing applications | |
| Mechanical Design | Device Dimensions | 230 mm × 127 mm × 55 mm |
| Host Weight | 1 kg | |
| Sensor Weight | 1.4 kg | |
| Operating Environment | Operating Temperature | -10℃ to 40℃ |
| Relative Humidity | 5%–90% RH | |
| Maximum Operating Altitude | Below 4500 m |
FAQs
Q1: How does an acoustic magnetic cable fault locator improve underground cable fault detection accuracy?
A: An acoustic magnetic cable fault locator combines sound and magnetic signal detection technologies to identify underground cable fault points more accurately. The system uses both acoustic and magnetic channels with a signal gain of more than 80 dB, helping technicians detect weak fault signals in complex environments.
Q2: What is the fixed point accuracy of an acoustic magnetic synchronous cable fault location system?
A: The acoustic magnetic synchronous cable fault location system can achieve a fixed point accuracy of up to 0.1 m. This high positioning accuracy helps power utilities and cable maintenance teams quickly locate underground cable faults and reduce repair time.
Q3: Can an acoustic magnetic cable fault detector work in areas with strong background noise?
A: Yes. The acoustic magnetic cable fault detector supports three background noise reduction modes, including strong noise reduction, adaptive noise reduction, and no noise reduction. These functions help improve fault location performance in noisy urban areas, industrial sites, and power distribution networks.
Q4: How long can a portable acoustic magnetic cable fault locator operate after a full charge?
A: A portable acoustic magnetic cable fault locator uses a built-in 3.7 V lithium-ion battery with a capacity of 6700 mAh. It can work continuously for more than 9 hours, making it suitable for long-time outdoor underground cable fault testing.
Q5: Is this underground cable fault detection equipment suitable for outdoor power cable maintenance?
A: Yes. This underground cable fault detection equipment is designed for field applications. It features a sunlight-readable 800 × 480 color LCD display, a lightweight design, and a working temperature range of -10℃ to 40℃. It can be used for cable fault locating in power utilities, substations, and industrial power systems.
About Wrindu
Wrindu is a China OEM manufacturer of high voltage testing and power system testing equipment. The company develops and manufactures cable fault location equipment, insulation testers, transformer test equipment, partial discharge systems, and other electrical testing instruments. What's more, Wrindu provides OEM services for distributors, testing companies, and power industry customers.
| Item | Information |
|---|---|
| Manufacturer | Wrindu |
| Product Origin | Shanghai, China |
| OEM / ODM | Available |
| Technical Support | Available |
| Warranty | 1 year |
| User Support | Operation guidance and technical assistance |
| Spare Parts | Available according to product requirements |