RDJB-1600K 6 Phase Protection Relay Testing Kit | Wrindu
- Wrindu
- Shanghai, China
- about 10 working days
- 1000 set/month
- RDJB-1600K
The RDJB-1600K 6-Phase Protection Relay Tester was developed based on customer feedback and market research. It uses modern microelectronic technology to deliver accurate test results in a compact design. It combines the functions and performance of larger testing systems with the portability, flexibility, and ease of use of smaller units, making it a practical choice for relay protection testing.
Product Features
1. Multiple Output Configurations
Supports different combinations of six-phase voltage and current outputs, including four-current/three-voltage and six-phase output modes. It also supports three-phase transformer differential testing.
2. Flexible Operation
The unit can work on its own or be controlled through a laptop or desktop computer, making testing easier in different working environments.
3. Linear Power Amplifier
Uses modular linear amplifiers to provide stable output with low interference and accurate waveforms from high current to low current.
4. DSP-Based Control
DSP technology provides fast signal processing, wide bandwidth, and high-resolution D/A conversion. The unit delivers accurate waveforms with low distortion in a compact and portable design.
5. Practical Test Software
The software supports automatic test tasks, protection setting checks, fault playback, real-time data recording, vector display, and report printing. Six-phase current output also supports transformer differential protection tests.
6. Adjustable DC Output
Provides adjustable 110 V and 220 V DC power for different testing requirements.
7. USB Communication
A USB interface allows connection with computers and other external devices for data exchange and equipment control.
8. Built-In Protection
The unit includes a cooling system, hardware protection, soft-start function, and fault self-diagnosis to improve operating safety and reliability.
Product Specifications and Technical Parameters
Category | Item | Specifications |
|---|---|---|
AC Current Source | Six-phase current output (per phase, RMS) | 0–30 A |
Output accuracy | Class 0.2 | |
Three-phase current output (per phase, RMS) | 0–60 A | |
Six-phase parallel current output (RMS) | 0–180 A | |
Continuous current output (per phase) | 10 A | |
Maximum output power (per phase) | 300 VA | |
Maximum six-phase parallel output power | 1000 VA | |
Maximum operating time at six-phase parallel output | 10 s | |
Fundamental frequency range | 0–1000 Hz | |
Harmonic order | 2–20 | |
Phase angle | 0–360° | |
DC Current Source | Current output | 0–±10 A/phase |
Output accuracy | Class 0.5 | |
Maximum load voltage | 20 V | |
AC Voltage Source | Phase voltage output (RMS) | 0–120 V |
Output accuracy | Class 0.2 | |
Line voltage output (RMS) | 0–240 V | |
Phase/line voltage output power | 75 VA / 100 VA | |
Fundamental frequency range | 0–1000 Hz | |
Harmonic order | 2–20 | |
Phase angle | 0–360° | |
DC Voltage Source | Phase voltage output amplitude | 0–±160 V |
Output accuracy | Class 0.5 | |
Line voltage output amplitude | 0–±320 V | |
Phase/line voltage output power | 70 VA / 140 VA | |
Switching Terminals | Input channels | 8 |
Free contact input | 1–20 mA, 24 V | |
Potential contact – Logic 0 | 0 to +6 V | |
Potential contact – Logic 1 | +11 to +250 V | |
Output channels | 4 | |
Switching output | 110 V / 2 A; 220 V / 1 A | |
Time Measurement | Measurement range | 1 ms–9999 s |
Measurement accuracy | 1 ms | |
Power Supply | Input voltage | AC 220 V ±10% |
Frequency | 50 Hz |
What Applications Require a Six-Phase Protection Testing System?
A six-phase output system is useful when testing protection devices that require multiple current and voltage signals at the same time. It allows engineers to simulate different operating conditions without repeatedly changing test connections.
The RDJB-1600K is suitable for several testing tasks, including:
Transformer differential protection: Provides multiple current signals for checking differential protection response and phase relationships.
Multi-channel relay testing: Allows engineers to apply different current and voltage combinations during protection tests.
Protection setting verification: Helps check whether relay operating values match the configured settings.
Fault simulation: Generates adjustable electrical signals to simulate selected fault conditions.
Substation maintenance: Supports routine inspection and functional testing of protection devices.
The actual test configuration depends on the relay type, wiring arrangement, and testing procedure.
How Does Six-Phase Output Help with Transformer Differential Protection Testing?
Transformer differential protection compares current signals from different sides of a transformer. Differences in current magnitude and phase angle may indicate an internal fault or an abnormal operating condition.
During testing, engineers need to simulate current signals with specific amplitudes and phase relationships. A six-phase output system provides more channels for this work and helps reduce repeated connection changes.
The RDJB-1600K supports six-phase current output up to 30 A per phase and six-phase parallel output up to 180 A. Its adjustable phase angle and harmonic output also help engineers check relay response under different simulated conditions.
What Should Engineers Check Before Using a Relay Protection Test Set?
A suitable testing system should match the protection devices and test procedures used in the field. Before selecting or operating a unit, engineers should consider the following points:
| Selection Factor | What to Check |
|---|---|
| Output channels | Whether the available current and voltage channels meet the test requirements |
| Current capacity | Whether the output range is suitable for the relay under test |
| Voltage range | Whether the AC and DC outputs match the required test conditions |
| Phase adjustment | Whether the equipment supports the required phase angle settings |
| Frequency control | Whether the output frequency and harmonic range meet the testing needs |
| Software functions | Whether automatic testing, data recording, and report generation are required |
| Communication | Whether computer connection is needed for test control and data management |
The RDJB-1600K combines six-phase output, adjustable AC/DC signals, harmonic control, and computer communication in one testing system.
Why Are Test Records Important for Protection System Maintenance?
Test records help engineers compare relay performance over time and review changes after maintenance or setting adjustments. They also provide useful reference information when investigating unexpected relay operation.
The RDJB-1600K software supports real-time data storage, vector display, fault playback, and test report printing. These functions help organize test results and make it easier to review the conditions applied during a test.
For maintenance teams, keeping clear records can improve testing consistency and support future equipment inspections.
Where Can the RDJB-1600K Be Used?
The RDJB-1600K can support relay protection testing in different power system environments.
| Application Area | Typical Testing Tasks |
|---|---|
| Power substations | Protection relay inspection and functional verification |
| Transformer manufacturers | Transformer differential protection testing |
| Power generation plants | Checking relay response and protection settings |
| Electrical laboratories | Relay performance evaluation and simulated fault tests |
| Industrial power systems | Routine protection device maintenance |
| Testing and maintenance contractors | On-site relay testing and test report preparation |
The test setup should always follow the requirements of the protection device and the applicable testing procedure.
What Technical Support Does Wrindu Provide?
Wrindu is a power testing equipment manufacturer established in 2014. The company handles product development, manufacturing, and electrical testing solutions for customers in more than 120 countries.
For the RDJB-1600K, technical support can help customers understand output configurations, software functions, connection methods, and suitable testing applications. This is particularly useful when configuring multiple current and voltage channels for transformer differential protection tests.
Wrindu provides a one-year product warranty and technical guidance to support equipment operation and routine maintenance.