RDJB-1600K 6 Phase Protection Relay Testing Kit | Wrindu

  • 6 Phase Protection Relay Testing Kit, Six Phase Relay Test System, Transformer Differential Protection Tester, Six Phase Current Injection
  • 6 Phase Protection Relay Testing Kit, Six Phase Relay Test System, Transformer Differential Protection Tester, Six Phase Current Injection
  • 6 Phase Protection Relay Testing Kit, Six Phase Relay Test System, Transformer Differential Protection Tester, Six Phase Current Injection
  • 6 Phase Protection Relay Testing Kit, Six Phase Relay Test System, Transformer Differential Protection Tester, Six Phase Current Injection
  • 6 Phase Protection Relay Testing Kit, Six Phase Relay Test System, Transformer Differential Protection Tester, Six Phase Current Injection
6 Phase Protection Relay Testing Kit
  • Wrindu
  • Shanghai, China
  • about 10 working days
  • 1000 set/month
  • RDJB-1600K

The RDJB-1600K 6-Phase Protection Relay Tester was developed based on customer feedback and market research. It uses modern microelectronic technology to deliver accurate test results in a compact design. It combines the functions and performance of larger testing systems with the portability, flexibility, and ease of use of smaller units, making it a practical choice for relay protection testing.

Product Features


1. Multiple Output Configurations

Supports different combinations of six-phase voltage and current outputs, including four-current/three-voltage and six-phase output modes. It also supports three-phase transformer differential testing.

2. Flexible Operation

The unit can work on its own or be controlled through a laptop or desktop computer, making testing easier in different working environments.

3. Linear Power Amplifier

Uses modular linear amplifiers to provide stable output with low interference and accurate waveforms from high current to low current.

4. DSP-Based Control

DSP technology provides fast signal processing, wide bandwidth, and high-resolution D/A conversion. The unit delivers accurate waveforms with low distortion in a compact and portable design.

5. Practical Test Software

The software supports automatic test tasks, protection setting checks, fault playback, real-time data recording, vector display, and report printing. Six-phase current output also supports transformer differential protection tests.

6. Adjustable DC Output

Provides adjustable 110 V and 220 V DC power for different testing requirements.

7. USB Communication

A USB interface allows connection with computers and other external devices for data exchange and equipment control.

8. Built-In Protection

The unit includes a cooling system, hardware protection, soft-start function, and fault self-diagnosis to improve operating safety and reliability.


Product Specifications and Technical Parameters


Category

Item

Specifications

AC Current Source

Six-phase current output (per phase, RMS)

0–30 A

Output accuracy

Class 0.2

Three-phase current output (per phase, RMS)

0–60 A

Six-phase parallel current output (RMS)

0–180 A

Continuous current output (per phase)

10 A

Maximum output power (per phase)

300 VA

Maximum six-phase parallel output power

1000 VA

Maximum operating time at six-phase parallel output

10 s

Fundamental frequency range

0–1000 Hz

Harmonic order

2–20

Phase angle

0–360°

DC Current Source

Current output

0–±10 A/phase

Output accuracy

Class 0.5

Maximum load voltage

20 V

AC Voltage Source

Phase voltage output (RMS)

0–120 V

Output accuracy

Class 0.2

Line voltage output (RMS)

0–240 V

Phase/line voltage output power

75 VA / 100 VA

Fundamental frequency range

0–1000 Hz

Harmonic order

2–20

Phase angle

0–360°

DC Voltage Source

Phase voltage output amplitude

0–±160 V

Output accuracy

Class 0.5

Line voltage output amplitude

0–±320 V

Phase/line voltage output power

70 VA / 140 VA

Switching Terminals

Input channels

8

Free contact input

1–20 mA, 24 V

Potential contact – Logic 0

0 to +6 V

Potential contact – Logic 1

+11 to +250 V

Output channels

4

Switching output

110 V / 2 A; 220 V / 1 A

Time Measurement

Measurement range

1 ms–9999 s

Measurement accuracy

1 ms

Power Supply

Input voltage

AC 220 V ±10%

Frequency

50 Hz



What Applications Require a Six-Phase Protection Testing System?


A six-phase output system is useful when testing protection devices that require multiple current and voltage signals at the same time. It allows engineers to simulate different operating conditions without repeatedly changing test connections.


The RDJB-1600K is suitable for several testing tasks, including:

Transformer differential protection: Provides multiple current signals for checking differential protection response and phase relationships.

Multi-channel relay testing: Allows engineers to apply different current and voltage combinations during protection tests.

Protection setting verification: Helps check whether relay operating values match the configured settings.

Fault simulation: Generates adjustable electrical signals to simulate selected fault conditions.

Substation maintenance: Supports routine inspection and functional testing of protection devices.


The actual test configuration depends on the relay type, wiring arrangement, and testing procedure.


How Does Six-Phase Output Help with Transformer Differential Protection Testing?


Transformer differential protection compares current signals from different sides of a transformer. Differences in current magnitude and phase angle may indicate an internal fault or an abnormal operating condition.


During testing, engineers need to simulate current signals with specific amplitudes and phase relationships. A six-phase output system provides more channels for this work and helps reduce repeated connection changes.


The RDJB-1600K supports six-phase current output up to 30 A per phase and six-phase parallel output up to 180 A. Its adjustable phase angle and harmonic output also help engineers check relay response under different simulated conditions.


What Should Engineers Check Before Using a Relay Protection Test Set?


A suitable testing system should match the protection devices and test procedures used in the field. Before selecting or operating a unit, engineers should consider the following points:


Selection FactorWhat to Check
Output channelsWhether the available current and voltage channels meet the test requirements
Current capacityWhether the output range is suitable for the relay under test
Voltage rangeWhether the AC and DC outputs match the required test conditions
Phase adjustmentWhether the equipment supports the required phase angle settings
Frequency controlWhether the output frequency and harmonic range meet the testing needs
Software functionsWhether automatic testing, data recording, and report generation are required
CommunicationWhether computer connection is needed for test control and data management


The RDJB-1600K combines six-phase output, adjustable AC/DC signals, harmonic control, and computer communication in one testing system.


Why Are Test Records Important for Protection System Maintenance?


Test records help engineers compare relay performance over time and review changes after maintenance or setting adjustments. They also provide useful reference information when investigating unexpected relay operation.


The RDJB-1600K software supports real-time data storage, vector display, fault playback, and test report printing. These functions help organize test results and make it easier to review the conditions applied during a test.


For maintenance teams, keeping clear records can improve testing consistency and support future equipment inspections.


Where Can the RDJB-1600K Be Used?


The RDJB-1600K can support relay protection testing in different power system environments.


Application AreaTypical Testing Tasks
Power substationsProtection relay inspection and functional verification
Transformer manufacturersTransformer differential protection testing
Power generation plantsChecking relay response and protection settings
Electrical laboratoriesRelay performance evaluation and simulated fault tests
Industrial power systemsRoutine protection device maintenance
Testing and maintenance contractorsOn-site relay testing and test report preparation


The test setup should always follow the requirements of the protection device and the applicable testing procedure.


What Technical Support Does Wrindu Provide?


Wrindu is a power testing equipment manufacturer established in 2014. The company handles product development, manufacturing, and electrical testing solutions for customers in more than 120 countries.

For the RDJB-1600K, technical support can help customers understand output configurations, software functions, connection methods, and suitable testing applications. This is particularly useful when configuring multiple current and voltage channels for transformer differential protection tests.


Wrindu provides a one-year product warranty and technical guidance to support equipment operation and routine maintenance.


CE Certificate of Microcomputer Relay Protection Tester
CE Certificate of Microcomputer Relay Protection Tester
Mail consultation
Please feel free to give your inquiry in the form below. We will reply you in 24 hours.
close left right