Transformer Test Equipment
-
RDGYB-JD1000 Frequency Domain Dielectric Response Insulation Diagnostic Analyzer
The RDGYB-JD1000 Dielectric Response Testing System combines FDS/DFR and PDC technologies to provide accurate insulation condition analysis for transformers, bushings, cables, and rotating machines.
Email Details
With smart software and portable design, it can detect moisture, insulation aging, and deterioration, helping improve equipment reliability, reduce maintenance costs, and extend service life. -
RDBX-H Sweep Frequency Response Analyzer
RDBX-H Transformer Frequency Response Analyzer (FRA) uses advanced frequency response analysis technology to detect internal transformer faults. By measuring the winding characteristic parameters, it can accurately identify changes in transformer winding structure and help evaluate the internal condition of power transformers.
Email Details
During transportation, operation, or short-circuit faults, transformer windings may become deformed or displaced, causing changes in frequency response characteristics. RDBX-H can detect these changes and is suitable for internal fault diagnosis of 63kV–500kV power transformers. -
Transformer Ratio Tester Meter
In the production process of semi-finished and finished power transformers, before the newly installed transformers are put into operation, it is required to test the turn ratio or voltage ratio of the running transformers, so as to check the correctness of the turn ratio of transformers, the condition of tap changer.
Email Details -
Smart High Accuracy Turn Ratio Tester Transformer Ration Testing Equipment Portable Intelligent TTR Meter
RDB-IIH portable transformer turn ratio tester overcomes the shortcomings of traditional ratio bridge test, which is easy to operate and intuitive. It adopts three-phase precision inverter power supply, and has fast test and high accuracy.
Email Details -
Transformer Load and No Load Loss Tester
Transformer Load and No-Load Tester for precise measurement of low voltage short-circuit impedance in 35kV+ transformers, featuring advanced microcomputer technology, portable design, and efficiency enhancement.
Transformer Load No-Load And Capacity Tester Load And No-Load Tester For Transformers Transformer Capacity And Load No Load Loss TesterEmail Details -
Sweep Frequency Response Analyzer
The Sweep Frequency Response Analyzer evaluates transformers (6kV and above) for faults and accidents. Actively test transformer deformation to prevent power system accidents.
Sweep Frequency Response Analyzer Portable Sweep Frequency Response Analyzer response analysis techniquesEmail Details -
Hot
High quality Transformer DC Resistance Tester Winding Resistance Tester
The test transformer windings is a crucial testing tool used for various purposes in transformer manufacturing. It serves as a necessary test item for semi-finished products, finished products in factory testing, installation, overhaul, tap changer replacement, handover tests, and preventive tests conducted by power departments.
Email Details -
3 Phase DC Resistance tester
The RDZR-340Y 3 phase DC Resistance Tester is a cutting-edge solution for transformer manufacturing, offering simultaneous three-phase testing, rapid measurement, and comprehensive analysis to detect coil defects and operational risks. Its unique features include independent current/voltage sampling and real-time display of resistance and unbalance rates, significantly reducing test times for large power transformers.
Email Details -
Transformer Turn Ratio Tester
RDB- II transformer turns ratio tester overcomes the shortcomings of traditional ratio bridge test, which is easy to operate and intuitive. TTR tester adopts three-phase precision inverter power supply, and has fast test and high accuracy.
Email Details
In the production process of semi-finished and finished power transformers, before the newly installed transformers are put into operation and according to the preventive test regulations, it is required to test the turn ratio or voltage ratio of the running transformers, so as to check the correctness of the turn ratio of transformers, the condition of tap changer, whether the transformers are short circuited between turns, and whether the transformers can operate in parallel.