- RDER2100C+
The RDER2100C+ Multi-Function Clamp Earth Resistance Tester measures grounding resistance in power, telecommunications, construction, and industrial systems. It requires no grounding lead disconnection or auxiliary electrodes, making testing quick and easy. It also measures leakage and neutral currents for efficient grounding system inspection.
Product features
1. Self-test quickly, start immediately into the test.
2. Using the most advanced processing algorithms and digital integration technology.
3. The product is light weight, more in line with characteristics of hand-held devices.
4. New design, panel operation with 6 buttons, better performance.
5. Increase sound and light alarm function, with "beep-beep-beep” alarm sound.
6. Increase the interference signal recognition indicator function, with "beep-beep-beep” indicator.
7. Measurement range: resistance 0.01Ω ~1200Ω,current 0.00mA ~ 20.0A.
8. Stored data 99 Units. Lower power consumption, Maximum operating current less than 50mA.
For more grounding and insulation tester, please click insulation resistance tester list.
Product specifications and technical parameters
1. Measurement Range & Accuracy
Measurement | Range | Resolution | Accuracy |
Resistance | 0.010Ω ~ 0.099Ω | 0.001Ω | ±(1%rdg+0.01Ω) |
0.10Ω ~ 0.99Ω | 0.01Ω | ±(1%rdg+0.01Ω) | |
1.0Ω ~ 49.9Ω | 0.1Ω | ±(1%rdg+0.1Ω) | |
50.0Ω ~ 99.5Ω | 0.5Ω | ±(2%rdg+0.5Ω) | |
100Ω ~ 199Ω | 1Ω | ±(3%rdg+1Ω) | |
200Ω~395Ω | 5Ω | ±(6%rdg+5Ω) | |
400Ω~590Ω | 10Ω | ±(10%rdg+10Ω) | |
600Ω~880Ω | 20Ω | ±(20%rdg+20Ω) | |
900Ω~1200Ω | 30Ω | ±(25%rdg+30Ω) | |
Current | 0.00mA~9.95mA | 0.05mA | ±(2.5%rdg+1mA) |
10.0mA~99.0mA | 0.1mA | ±(2.5%rdg+5mA) | |
100mA~299mA | 1mA | ±(2.5%rdg+10mA) | |
0.30A~2.99A | 0.01A | ±(2.5%rdg+0.1A) | |
3.0A~9.9A | 0.1 A | ±(2.5%rdg+0.3A) | |
10.0A~19.9A | 0.1 A | ±(2.5%rdg+0.5A) |
2. Technical Parameters
Function | Description |
Power Supply | 6VDC 4 PCS LR6 lkaline batteries |
Clamp Size | Φ32mm |
LCD Size | 4 Digits LCD display, Screen: 47mm×28.5mm |
Range | Resistance 0.01Ω-1200Ω,current 0.00mA~20.0A. |
Resolution | Resistance 0.001Ω,current 0.05mA |
Accuracy | Resistance ±1%±0.01Ω,current ±2.5%rdg±1mA |
Data Storage | 99 sets |
Data Upload Function | RS232 Interface (Optional) |
Auto Shutdown | Automatically power off after 5 minutes without any operate |
Power Consumption | ≤50mA, Continuously working for 30 hours |
Working Environment | -20℃~55℃ 20%~80%RH |
Store Environment | -20℃~60℃; below 90%RH |
Alarm Threshold Setting Range | Resistance: 1~199Ω, current 1~499mA. |
Audible and VisibleAlarm | "Beep-beep-beep” alarm sound, alarm symbol flashing, pressALkey to turn on/off and setting |
Interference Signal Recognition | "Beep-beep-beep” indicator,NOISE symbol blinking |
Protection Level | Double insulation |
Structural Feature | Clamp CT |
Shift | Automatic shift |
External Magnetic Field | <40A/m |
External Electrical Field | <1V/m |
Single Measurement Time | 0.5 second |
Resistance Measurement Frequency | >1KHz |
Measured Current Frequency | 50/60Hz Automatic |
Low Battery Voltage Indicator | When the battery voltage is lower than 5.3V, the low battery voltage symbol is displayed |
Storage Full Indication | Storage data full of 99 sets,flashed display "MEM" symbol |
Over Range Indication | Exceed range indication “OLΩ”, “L0.01” or “OL A” |
Tester Weight | 1160g |
Tester Dimension | 285mm×85mm×56mm |
Where Can the RDER2100C+ Be Used?
The RDER2100C+ Multi-Function Clamp Earth Resistance Tester is suitable for grounding system inspections in power utilities, telecommunications, industrial plants, construction sites, oilfields, and meteorological facilities. It measures grounding resistance in suitable closed-loop systems without disconnecting the grounding lead or using auxiliary electrodes.
How to Use the Tester?
1. Check the tester, clamp, and battery before use.
2. Confirm that the grounding system has a suitable closed loop.
3. Clamp the instrument around the grounding conductor.
4. Read and record the resistance or current value.
5. If interference occurs or readings appear unusual, check the setup and repeat the measurement.
Note: Clamp measurement may not work correctly on an isolated grounding electrode without a suitable return path.
Measurement Accuracy and Safety
Measurement accuracy varies by range. Check the detailed specifications before evaluating results. Keep the clamp clean and fully closed, and avoid strong interference where possible.
Follow the product manual and site safety procedures when working near electrical installations. Double insulation does not eliminate the need for proper protective equipment and safe operation.
Why Choose Wrindu-OEM HV Manufacturer?
Wrindu provides electrical testing equipment for power and industrial applications. Contact the Wrindu team for detailed specifications, product configuration, and technical support for your grounding measurement requirements.