China Manufacturer Secondary Injection Tester 6 Phase Power Protective Relay Testing Set
- Wrindu
- Shanghai
- About 10 working days
- 5000 set/month
- RDJB-1600M
The RDJB-1600M Microcomputer Relay Protection Tester was developed by Wrindu based on user feedback and an evaluation of similar products available on the domestic market.
Product Features
1. Flexible Voltage and Current Output
The RDJB-1600M provides six-phase voltage and six-phase current output. Users can select different output combinations, including four-phase current with three-phase voltage, six-phase voltage, six-phase current, or 12-phase output. These options support a wide range of relay protection tests, including three-phase transformer differential protection testing.
2. Standalone and Computer Operation
The tester can operate independently or connect to a laptop or desktop computer. This gives users more flexibility when performing different types of relay protection tests.
3. Linear Power Amplifier
The device uses a modular linear power amplifier instead of a switching power amplifier. This design helps reduce high-frequency interference and provides stable waveform output across a wide current range, from high current to low current.
4. DSP-Based Control System
The tester uses digital signal processing (DSP) for output control and real-time signal processing. Its system supports accurate waveform generation, low distortion, and good linearity. The compact design also makes the device easier to transport and use for field testing.
5. Powerful Testing Software
The software supports automatic relay verification, protection setting checks, fault playback, real-time data storage, vector display, and test report printing. Six-phase current output also supports three-phase transformer differential protection testing.
6. Adjustable DC Power Output
The tester provides an independent DC power output adjustable to 110 V or 220 V, supporting relay protection testing that requires an auxiliary DC supply.
7. USB Communication Interface
A USB port allows the tester to connect to a computer or other compatible external devices for communication and data transfer.
8. Multiple Protection Functions
The device includes a heat dissipation design and hardware protection measures. It also features soft-start power control, fault self-diagnosis, and output latching to help protect the instrument during operation.
For more Relay Protection Testers, click the Relay list.
Product Specifications and Technical Parameters
Category | Parameter | Technical Specifications |
|---|---|---|
AC Current Source | Six-phase current output | 0–30 A per phase |
Three-phase current output | 0–60 A per phase | |
Six-phase parallel current output | 0–180 A | |
Output accuracy | 0.2 grade | |
Continuous operating current per phase | 10 A | |
Maximum output power per phase | 450 VA | |
Maximum output power (six-phase parallel) | 1000 VA | |
Maximum operating time at six-phase parallel output | 10 s | |
Fundamental frequency range | 0–1000 Hz | |
Harmonic order | 2–20 | |
Phase angle | 0–360° | |
DC Current Source | Current output | 0–±10 A per phase |
Output accuracy | 0.5 grade | |
Maximum load voltage | 20 V | |
AC Voltage Source | Phase voltage output | 0–120 V |
Line voltage output | 0–240 V | |
Output accuracy | 0.2 grade | |
Output power (phase/line voltage) | 80 VA / 100 VA | |
Fundamental frequency range | 0–1000 Hz | |
Harmonic order | 2–20 | |
Phase angle | 0–360° | |
DC Voltage Source | Phase voltage output | 0–±160 V |
Line voltage output | 0–±320 V | |
Output accuracy | 0.5 grade | |
Output power (phase/line voltage) | 70 VA / 140 VA | |
Switching Terminals | Input channels | 8 channels |
Free contact input | 1–20 mA, 24 V | |
Logic level “0” | 0 to +6 V | |
Logic level “1” | +11 to +250 V | |
Output channels | 4 channels | |
DC output capacity | 220 V / 0.2 A | |
AC output capacity | 220 V / 0.5 A | |
Time Measurement | Measurement range | 0.1 ms–9999 s |
Measurement accuracy | Less than 0.1 ms | |
Power Supply | Supply voltage | AC 220 V ±10% |
Frequency | 50 Hz |
Note: Confirm the meaning of the stated accuracy grades, applicable measurement conditions, and output limits against the official technical manual before using these specifications for contractual comparisons.
How to Select a Relay Protection Tester?
Selecting a relay protection tester requires more than comparing the maximum current and voltage outputs. Testing teams should also consider the relay type, required phase configuration, output accuracy, auxiliary power requirements, and test software functions.
Phase configuration: Confirm whether the application requires three-phase, six-phase, or other supported output combinations.
Current capacity: Check the required test current and duration. The RDJB-1600M's maximum six-phase parallel output is rated for a maximum of 10 seconds.
Voltage requirements: Verify that the AC and DC output ranges meet the relay's test requirements.
Timing and switching: Confirm that the input and output channels are suitable for the relay's contact signals and operating-time tests.
Software functions: Check whether the required automatic test routines, fault playback, vector display, and reporting functions are included in the supplied software.
Power and safety: Confirm the site power supply, wiring requirements, grounding arrangements, and operating limits before testing.
Frequently Asked Questions
What is the RDJB-1600M Relay Protection Tester used for?
The RDJB-1600M is used to verify protective relay operation, check protection settings, simulate electrical fault conditions, and measure relay operating time. It also supports multi-phase testing for applications such as transformer differential protection.
Can the RDJB-1600M test three-phase transformer differential protection?
Yes. Its six-phase current output supports three-phase transformer differential protection testing. The exact test method depends on the transformer configuration, relay design, current transformer ratios, and required test procedure.
What is the maximum current output of the RDJB-1600M?
The specified six-phase parallel current output reaches 180 A, with a maximum output power of 1000 VA and a maximum operating time of 10 seconds at the maximum output. The specified three-phase current output is up to 60 A per phase.
Does the RDJB-1600M support computer-controlled testing?
Yes. The tester supports standalone operation and connection to a compatible computer through USB. Supported software functions include relay verification, fault playback, data storage, vector display, and report printing.
What should users check before purchasing a relay protection tester?
Users should confirm the required output configuration, current and voltage ranges, accuracy requirements, timing functions, switching interfaces, software modules, and auxiliary DC supply requirements. These factors help determine whether the tester is suitable for the intended relay models and testing procedures.
Technical Support and Service
Wrindu provides technical consultation to help customers select suitable relay protection testing equipment for their applications. Before ordering, customers can provide the relay type, required current and voltage ranges, phase configuration, and intended testing tasks for a compatibility review.
For project-specific requirements, request confirmation of the supplied software functions, accessories, operating manual, warranty terms, and technical support arrangements before purchase.